WTR
S
1
7
M
RELAY #1
4
B
RLY
A
MAIN POWER
SWITCH
BIN SIGNAL
T- S TAT
SWITCH
(220/230 VAC)
ICE MACHINE
POWER
RED
RD RD
ORANGE
RED
PUR
ORANGE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
321
TIMER
BLK
BLK
BLK
PURPLE
PUR
WHITE
BLACK
ORANGE
RED
4
7
RELAY #2
1
ICE MACHINE
BIN SIGNAL
(16 VDC)
4x4 JUNCTION BOX
230V 50HZ
220V 60HZ
GREEN/YELLOW
BLUE
BROWN
BLACK
BLUE
WHITE
GREEN
BLACK
#2
A
RLY
B
#1
Service information
Wiring diagrams
How unit works — lever models
The dispense wheel motor and dispense solenoid are energized through the power and ice dispense switches. The water
solenoid valve is energized through the power and water dispense switches. The icemaker receives the bin signal through
the power switch, the normally closed bin thermostat and the icemaker switch. When the bin level thermostat is calling for
ice, a 115V bin signal is applied to the bin signal terminals on the icemaker circuit board.
When ice builds up around the bin
thermostat, the contacts open, cutting the bin signal to the icemaker.