Mechanical system
Evaporator disassembly
1. Press PURGE button to purge evaporator, and then
turn power OFF.
2. Unscrew and remove stream divider as shown.
3. Unplug and remove gearmotor as shown.
4. Remove all traces of anti-seize compound or petrol-
gel from the auger shaft.
5. Unscrew and disconnect transport tube from
louvered docking assembly.
6. Unplug sensor at the electrical box.
7. Remove vent tube from shuttle housing as shown.
Fig. 13