Lube
with soap
touch
Do not
Cardboard
disc
Fig. 19
3. Press new mating ring into main housing as shown.
4. Lube the shaft with liquid soap in the area shown
and slip on seal and spring.
Note: Do not touch the sealing surfaces. Use
cardboard disk to install.
Fig. 20
5. Reinstall main housing as shown.
Fig. 18
Evaporator reassembly
1. Remove and inspect O ring seal. Discard if
damaged in any way.
2. Clean O ring groove. Lubricate O ring and reinstall.